Graco E-10 (unheated)                                         Graco E-XP1

              

Graco E-XP 2                                                      Airless Spray Rig

 

                   

Speedliner® Cartridge Gun                               Speedliner® 1000 Hopper Gun

 

Speedliner® 1000 Pressure Pot

 

                     

 

ELECTRICAL REQUIREMENTS

  • E-XP-2 (High Pressure) Max: 230 V, 3 phase, 60 amp
  •  E XP-2 (High Pressure) Max: 230 V, 1 phase, 100 amp
  • E-10 (Low Pressure) Max: 120 V, 20 amp

 

COMPRESSOR  (E-10 & E-XP-2 only)

  • Minimum 7.5 HP (220 V, 1 phase, 35 amp) two stage with 80-gallon tank capable of 25 CFM @ 100 psi to be used exclusively for equipment only.  Automatic drain is highly recommended.
  • Minimum 10 HP with 120-gallon tank may be necessary if others in the shop will be using air tools simultaneously.

COMPRESSOR  (Cartrige Gun & Hopper Gun only)

  • Minimum 3 HP (230 V, 1 phase) 2 cylinder with 60-gallon tank capable of 11.3 CFM @ 90 psi to be used exclusively for equipment only.  Automatic drain is highly recommended.
  • Minimum 5 HP with 80-gallon tank may be necessary if others in the shop will be using air tools simultaneously.

 

REFRIGERANT DRYER

  • The spray air needs to be less than 5% relative humidity as it leaves the gun.
  • A 3-in-1 refrigerant dryer for you compressor is mandatory.

 

EQUIPMENT & MATERIAL ROOM (E-10 & E-XP-2 only)

  • Minimum 10ft wide X 10ft long X 8ft high fully insulated walls and ceiling.
  • Recommended to be located next to spray room with common wall to spray area.
  • Heated vents located on 3 corners at bottom of wall 2 ft from the floor.
  • Air intake on 1 corner at bottom of the wall 2 ft from the floor.
  • Heater must be capable of maintaining the room at 80F – 90F 24 hrs a day, 7 days a week.  No open flame heaters.  Radiant or infrared heater with adjustable thermostat works best.
  • A small A/C window unit may be necessary in parts of the country where shop temperatures reach 100F.

 

APPLICATION AREA - for truck bedliners only

  • One truck:  16ft wide x 16ft deep x 11ft high (minimum)
  • Two trucks: 24ft wide x 18ft deep x 11ft high (minimum)
  • Flourescent lighting
  • Tar paper on floor with duct tape
  • Polyethylene curtains capable of completely enclosing spray area (NFPA 701 compliant)
  • Ventilation fans must exhaust air 2-3 times per minute.  Forced makeup air will be required.  Heated air will be needed in colder climates.  Note:  To determine the CFM of exhaust fan, take total volume of the room and double that number.  3,000 cu ft room will require 6,000 cu ft fan.